Polypropylene(PP) insulation, Nitrile rubber(NBR) jacket, Full galvanized steel (or stainless steel or Monel) tape armour.
Performing Criterion:
GB/T16750、IEEE1017.2、IEEE1018、IEEE1019、API RP11S5、API RP11S6
Application Range:
This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV. The permissible working temperature is 90℃(194℉). The cable has the excellent ability of oil-resistance and corrosion-resistance.
Phase | Cross Section mm2 | Conductor Diameter mm | DC Resistance at 20℃ ≤ Ω/km Untinned Tinned | Insulation Thickness mm 3kV 6kV | Jacket Thickness mm | Overall Size and Weight 3kV 6kV mm kg/km mm kg/km | |||||||||||||||||||||||
3 | 16 | 1/4.62 | 1.15 | 1.16 | 2.0 | 2.3 | 2.0 | 27 | 1381 | 29 | 1480 | ||||||||||||||||||
3 | 20 | 1/5.19 | 0.84 | 0.86 | 2.0 | 2.3 | 2.0 | 28 | 1555 | 31 | 1650 | ||||||||||||||||||
3 | 33 | 1/6.54 | 0.54 | 0.56 | 2.0 | 2.3 | 2.0 | 32 | 2060 | 34 | 2170 | ||||||||||||||||||
3 | 42 | 1/7.35 | 0.43 | 0.44 | 2.0 | 2.3 | 2.0 | 34 | 2382 | 37 | 2500 |
Cross Section | Conductor Diameter mm | 3kV Insulation Resistance M Ω ·km | 3kV Leakage Current at 15.6℃ μA/km/kV | 6kV Insulation Resistance M Ω ·km | 6kV Leakage Current μA/km/kV | DC Voltage Test For 5 Minutes | |||||||||||||||||||||||
mm2 | AWG | 3kV | 6kV | ||||||||||||||||||||||||||
16 | 5 | 4.62 | 4500 | 0.278 | 5400 | 0.246 | |||||||||||||||||||||||
20 | 4 | 5.19 | 3380 | 0.295 | 3869 | 0.262 | 27kV | 35kV | |||||||||||||||||||||
33 | 2 | 6.54 | 2530 | 0.394 | 2922 | 0.328 | |||||||||||||||||||||||
42 | 1 | 7.35 | 2300 | 0.427 | 2658 | 0.361 |