EPDM insulation, Inner lead sheath, Fluoropolymer tape and synthetic braid covered completely over the lead
sheath, Outer nitrile rubber(NBR) jacket, Full galvanized steel (or stainless steel or Monel) tape armour.
Performing Criterion:
GB/T16750、IEEE1017.2、IEEE1018、IEEE1019、API RP11S5、API RP11S61
Application Range:
This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV.
The maximum permissible conductor temperature is 205 ℃ (400 ℉ ). The cable has the excellent ability of
oil-resistance, heat-resistance and corrosion-resistance.
Phase | Cross Section mm2 | Conductor Diameter mm | DC Resistance at 20℃ ≤ Ω/km Untinned Tinned | Insulation Thickness mm 3kV 6kV | Jacket Thickness mm InnerOuter | Overall Size and Weight 3kV 6kV mm kg/km mm kg/km | |||||||||||||||||||||||
3 | 16 | 1/4.62 | 1.15 | 1.16 | 2.0 | 2.3 | 1.0 | 2.0 | 32 | 2082 | 33 | 2293 | |||||||||||||||||
3 | 20 | 1/5.19 | 0.84 | 0.86 | 2.0 | 2.3 | 1.0 | 2.0 | 34 | 2399 | 35 | 2577 | |||||||||||||||||
3 | 33 | 1/6.54 | 0.54 | 0.56 | 2.0 | 2.3 | 1.0 | 2.0 | 36 | 3120 | 37 | 3176 | |||||||||||||||||
3 | 42 | 1/7.35 | 0.43 | 0.44 | 2.0 | 2.3 | 1.0 | 2.0 | 38 | 3310 | 39 | 3566 |
Cross Section | Conductor Diameter mm | 3kV Insulation Resistance M Ω ·km | 3kV Leakage Current at 15.6℃ μA/km/kV | 6kV Insulation Resistance M Ω ·km | 6kV Leakage Current μA/km/kV | DC Voltage Test For 5 Minutes | |||||||||||||||||||||||
mm2 | AWG | 3kV | 6kV | ||||||||||||||||||||||||||
16 | 5 | 4.62 | 1484 | 0.7 | 1692 | 0.607 | 27kV 35kV | ||||||||||||||||||||||
20 | 4 | 5.19 | 1352 | 0.775 | 1548 | 0.656 | |||||||||||||||||||||||
33 | 2 | 6.54 | 1012 | 0.984 | 1170 | 0.853 | |||||||||||||||||||||||
42 | 1 | 7.35 | 919 | 1.083 | 1063 | 0.951 |