● Description
Compound insulation with polyimide film and EPDM rubber, Inner lead sheath, Fluoropolymer tape and synthetic braid covered completely over the jacket, Full galvanized steel (or stainless steel or Monel) tape armour.
● Performing Criterion
GB/T16750、IEEE1017、IEEE1018、IEEE1019、API RP11S5、API RP11S6
● Application Range
This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV. The permissible working temperature is 150℃(302℉). The cable has the excellent ability of oil-resistance, heat-resistance and corrosion-resistance.
● Cable’s Cross Section Chart
● Specification and Parameters
Phase
| Cross Section mm2 | Conductor Diameter mm | DC Resistance at 20℃ ≤Ω/km | Insulation Thickness mm | Jacket Thickness mm | Overall Size and Weight | ||||||
3kV | 6kV | |||||||||||
Untinned | Tinned | 3kV | 6kV | 3kV | 6kV | mm×mm | kg/km | mm×mm | kg/km | |||
3 | 16 | 1/4.62 | 1.15 | 1.16 | 1.9 | 2.3 | 1.0 | 1.0 | 13×36 | 2230 | 13×38 | 2430 |
3 | 20 | 1/5.19 | 0.84 | 0.86 | 1.9 | 2.3 | 1.0 | 1.0 | 14×38 | 2464 | 14×40 | 2752 |
3 | 33 | 1/6.54 | 0.54 | 0.56 | 1.9 | 2.3 | 1.0 | 1.0 | 15×43 | 3143 | 15×45 | 3348 |
3 | 42 | 1/7.35 | 0.43 | 0.44 | 1.9 | 2.3 | 1.0 | 1.0 | 16×45 | 3575 | 16×47 | 3881 |
● Cable’s Cross Section Chart
Cross Section | Conductor Diameter mm | 3kV Insulation Resistance MΩ·km | 3kV Leakage Current at 15.6℃ μA/km/kV | 6kV Insulation Resistance MΩ·km | 6kV Leakage Current μA/km/kV | DC Voltage Test For 5 Minutes | ||
mm2 | AWG | 3kV | 6kV | |||||
16 | 5 | 4.62 | 1797 | 0.56 | 2035 | 0.49 | 27kV | 35kV |
20 | 4 | 5.19 | 1614 | 0.62 | 1835 | 0.54 | ||
33 | 2 | 6.54 | 1503 | 0.67 | 1713 | 0.58 | ||
42 | 1 | 7.35 | 1347 | 0.74 | 1542 | 0.65 |