Availability: | |
---|---|
Quantity: | |
Compound insulation with polyimide film and EPDM rubber, Inner lead sheath, Fluoropolymer tape and synthetic
braid covered completely over the lead sheath, Outer nitrile rubber(NBR) jacket, Full galvanized steel (or stainless
steel or Monel) tape armour.
Performing Criterion:
GB/T16750、IEEE1017.2、IEEE1018、IEEE1019、API RP11S5、API RP11S6
Application Range:
This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV.
The permissible working temperature is 150 ℃ (302 ℉ ). The cable has the excellent ability of oil-resistance,
heat-resistance and corrosion-resistance.
Phase | Cross Section mm2 | Conductor Diameter mm | DC Resistance at 20℃ ≤ Ω/km | Insulation Thickness mm 3kV 6kV | Jacket Thickness mm | Overall Size and Weight 3kV 6kV mm kg/km mm kg/km | |||||||||||||||||||||||
Inner | Outer | ||||||||||||||||||||||||||||
3 3 3 3 | 16 20 33 42 | 1/4.62 1/5.19 1/6.54 1/7.35 | 1.15 0.84 0.54 0.43 | 0.8 0.8 0.8 0.8 | 1.0 1.0 1.0 1.0 | 1.0 1.0 1.0 1.0 | 2.0 2.0 2.0 2.0 | 32 34 36 38 | 2310 2678 3055 3560 | 34 36 38 40 | 2491 3002 3310 3766 |
Cross Section | Conductor Diameter mm | 3kV Insulation Resistance M Ω ·km | 3kV Leakage Current at 15.6℃ μA/km/kV | 6kV Insulation Resistance M Ω ·km | 6kV Leakage Current μA/km/kV | DC Voltage Test For 5 Minutes | |||||||||||||||||||||||
mm2 | AWG | 3kV | 6kV | ||||||||||||||||||||||||||
16 | 5 | 4.62 | 5112 | 0.240 | 5978 | 0.20 | |||||||||||||||||||||||
20 | 4 | 5.19 | 4660 | 0.270 | 5431 | 0.23 | 27kV | 35kV | |||||||||||||||||||||
33 | 2 | 6.54 | 3905 | 0.344 | 4516 | 0.284 |