Polypropylene(PP) insulation, Nitrile rubber(NBR) jacket, Fluoropolymer tape and synthetic braid covered
completely over the jacket, Full galvanized steel (or stainless steel or Monel) tape armour.
Performing Criterion:
GB/T16750、IEEE1017.2、IEEE1018、IEEE1019、API RP11S5、API RP11S6
Application Range:
This cable is applicable for use in Electricity Submersible Pump Units with rated voltage less than 3kV or 6kV. The permissible working temperature is 90℃(194℉). The cable has the excellent ability of oil-resistance and corrosion-resistance.
Phase | Cross Section mm2 | Conductor Diameter mm | DC Resistance at 20℃ ≤ Ω/km | Insulation Thickness mm 3kV 6kV | Jacket Thickness mm 3kV 6kV | Overall Size and Weight | 6kV | kg/km | ||||||||||||||||||||
3KV mm×mm kg/km | ||||||||||||||||||||||||||||
mm×mm | ||||||||||||||||||||||||||||
3 | 16 | 1/4.62 | 1.16 | 1.9 | 2.3 | 1.0 | 1.0 | 14×37 | 1278 | 18×42 | 1390 | |||||||||||||||||
3 | 20 | 1/5.19 | 0.86 | 1.9 | 2.3 | 1.0 | 1.0 | 15×39 | 1449 | 19×44 | 1580 | |||||||||||||||||
3 | 33 | 1/6.54 | 0.56 | 1.9 | 2.3 | 1.0 | 1.0 | 16×44 | 1643 | 21×50 | 1760 | |||||||||||||||||
3 | 42 | 1/7.35 | 0.44 | 1.9 | 2.3 | 1.0 | 1.0 | 17×47 | 2158 | 22×54 | 2270 |
Cross Section | Conductor Diameter mm | 3kV Insulation Resistance M Ω ·km | 3kV Leakage Current at 15.6℃ μA/km/kV | 6kV Insulation Resistance M Ω ·km | 6kV Leakage Current μA/km/kV | DC Voltage Test For 5 Minutes | ||||||||||||||||||||||
mm2 | AWG | 3kV | 6kV | |||||||||||||||||||||||||
16 | 5 | 4.62 | 4500 | 0.278 | 5400 | 0.246 | ||||||||||||||||||||||
20 | 4 | 5.19 | 3380 | 0.295 | 3869 | 0.262 | 27kV | 35kV | ||||||||||||||||||||
33 | 2 | 6.54 | 2530 | 0.394 | 2922 | 0.328 | ||||||||||||||||||||||
42 | 1 | 7.35 | 2300 | 0.427 | 2658 | 0.361 |